-
Bimetal Thermometers (DIN 16160-2) (IP65)
THERMOMETERS, THERMOMETERS, Without Contact, Without ContactType: TEK 14 TEK 16 TEK A 16 Measuring Principle: Bimetal Connections Diameter: G½ ” G1” G¾” Switch Rating: 5A125VAC / 3A250VAC -
BR25-F16
Gas and Oil Actuated (Buchholz) Relay, Gas and Oil Actuated (Buchholz) RelayGas and Oil Actuated (Buchholz) Relay (EN 50216-2 and DIN 42566) (IP65)
Type: BR25-F16 Max. Number of Switches: 2 Nominal Diameter: Dn 25 Connection Type: Flanged For transformer capacity (kVA): ≤1600 -
BR25-F50
Gas and Oil Actuated (Buchholz) Relay, Gas and Oil Actuated (Buchholz) RelayGas and Oil Actuated (Buchholz) Relay (EN 50216-2 and DIN 42566) (IP65)
Type: BR25-F50 Max. Number of Switches: 2 Nominal Diameter: Dn 25 Connection Type: Flanged For transformer capacity (kVA): ≤ 5000 -
BR25-V16
Gas and Oil Actuated (Buchholz) Relay, Gas and Oil Actuated (Buchholz) RelayGas and Oil Actuated (Buchholz) Relay (EN 50216-2 and DIN 42566) (IP65)
Type: BR25-V16 Max. Number of Switches: 2 Nominal Diameter: Dn 25 Connection Type: Pipe thread R1 ½” For transformer capacity (kVA): ≤ 1600 -
BR25-V50
Gas and Oil Actuated (Buchholz) Relay, Gas and Oil Actuated (Buchholz) RelayGas and Oil Actuated (Buchholz) Relay (EN 50216-2 and DIN 42566) (IP65)
Type: BR25-V50 Max. Number of Switches: 2 Nominal Diameter: Dn 25 Connection Type: Pipe thread R1 ½” For transformer capacity (kVA): ≤ 5000 -
BR50-F100
Gas and Oil Actuated (Buchholz) Relay, Gas and Oil Actuated (Buchholz) RelayGas and Oil Actuated (Buchholz) Relay (EN 50216-2 and DIN 42566) (IP65)
Type: BR50-F100 Max. Number of Switches: 2 Nominal Diameter: Dn 50 Connection Type: Flanged For transformer capacity (kVA): ≥ 5000 - ≤ 10000 -
BR80-F100
Gas and Oil Actuated (Buchholz) Relay, Gas and Oil Actuated (Buchholz) RelayGas and Oil Actuated (Buchholz) Relay (EN 50216-2 and DIN 42566) (IP65)
Type: BR80-F100 Max. Number of Switches: 2 Nominal Diameter: Dn 80 Connection Type: Flanged For transformer capacity (kVA): ≥ 10000 -
BR80-KF100
Gas and Oil Actuated (Buchholz) Relay, Gas and Oil Actuated (Buchholz) RelayGas and Oil Actuated (Buchholz) Relay (EN 50216-2 and DIN 42566) (IP65)
Type: BR80-KF100 Max. Number of Switches: 2 Nominal Diameter: Dn 80 Connection Type: Square Flanged For transformer capacity (kVA): ≥ 10000 -
Bushings
COMEMCRS Bushings: https://emdltd.com.tr/wp-content/uploads/2019/06/CRS-Bushings.pdf Epoxy Resin Bushings: https://emdltd.com.tr/wp-content/uploads/2019/06/PPS-PPQ-BT-PIAS-Resine-Insulators.pdf Porcelain Bushings and Flags- Connecting Flags for Bushings: https://emdltd.com.tr/wp-content/uploads/2019/06/Connecting-Flags-for-Bushings.pdf
- Porcelain Bushings: https://emdltd.com.tr/wp-content/uploads/2019/06/Porcelain-Bushings.pdf
-
COT Type Linear Tap Changer
(DECT) TAP CHANGERS (LINEER - ROTARY), (DECT) TAP CHANGERS (LINEER – ROTARY)Linear Type: COT (Cable Operated Tap Changer) Voltage (kV): 20 - 30 Current (A): 30 – 63 Number of Positions: 3 - 7 Connection: Delta, Star, Series–Parallel, Common–Output per Phase -
Custom Design Bushings
Custom Design Bushings, Custom Design BushingsKonabilecek Tipler:- AP
- Riyad Baralı
- Alttan Baralı
- Enver tipi
- HV Bushings 52kV and from 250A to 630A
- 250A – 630A Alt Ark Milli
- Unel Tipi
- LV Bushings 3kV and from 4500A to 6500A
-
Dial Thermometers
THERMOMETERS, THERMOMETERS, With Contact, With ContactType: DBT Measuring Principle: Bimetal Nominal Size: 75 - 100 Measuring Range: 00C ~1200C -
DIN 42562 – NAK
MOISTURE HOLDERS, MOISTURE HOLDERSType: NAK Silica Gel Capacity (kg): 1.2 – 2.4 – 3.6 – 4.8 – 6 Reservoir Material: Glass / Polycarbonate -
DIN 42567 – FORM A
MOISTURE HOLDERS, MOISTURE HOLDERSType: FORM A Silica Gel Capacity (kg): 0.5 – 1 Reservoir Material: Glass / Polycarbonate -
DIN 42567 – FORM B
MOISTURE HOLDERS, MOISTURE HOLDERSType: FORM B Silica Gel Capacity (kg): 0.5 – 1 Reservoir Material: Glass / Polycarbonate -
DIN 42567 – FORM C
MOISTURE HOLDERS, MOISTURE HOLDERSType: FORM C Silica Gel Capacity (kg): 0.5 – 1 Reservoir Material: Glass / Polycarbonate -
DIN 42567 – FORM D
MOISTURE HOLDERS, MOISTURE HOLDERSType: FORM D Silica Gel Capacity (kg): 0.72 – 5 – 10 – 25.2 – 43.2 Reservoir Material: Glass / Polycarbonate -
Direct Mount Thermometers (DIN 16160-2)
THERMOMETERS, THERMOMETERS, With Contact, With ContactType: TES 14 TES 16 TES A 16 Connections Diameter: G½” G1” G¾” Measuring Principle: Bimetal Measuring Range: 100C ~ 1200C Probe Length (mm): 110 - 150 - 200 -
Epoxy-Resin Monoblock Bushing (BS 2562 – EN 50336)
EN BUSHINGS (HV-LV), EN BUSHINGS (HV-LV)Epoxy-Resin Monoblock Bushing (BS 2562 – EN 50336) Nominal Voltage (kV): 1.1 Rated Current (A): 800 – 1400 – 1600 – 2500 -
Epoxy-Resin Plug-In Bushing 24kV – 36kV and 250A – 1250A (EN 50180 and EN 50181)
EN BUSHINGS (HV-LV), EN BUSHINGS (HV-LV)Epoxy-Resin Plug-In Bushing 24kV - 36kV and 250A – 1250A (EN 50180 and EN 50181) -
Gas Density Monitors
QUALİTROLAP-B14-02L-01E_AKM_387501: https://emdltd.com.tr/wp-content/uploads/2019/06/AP-B14-02L-01E_AKM_387501.pdf About Qualitrol: https://emdltd.com.tr/wp-content/uploads/2019/06/Qualitrol.pdf -
Gas Filled Thermometers (IP41)
THERMOMETERS, THERMOMETERS, Without Contact, Without ContactType: RMT 3 RMT 5 Capillary Length (m): 3 5 Measuring Principle: Capillary (Gas Filled) Dial Diameter: 100 - 160 Measuring Range: 00C ~1200C / 00C ~1600C -
GKM Remote Control System
(DECT) TAP CHANGERS (LINEER - ROTARY), (DECT) TAP CHANGERS (LINEER – ROTARY)Type: GKM Code No for KDZ 120 A: 81 Code No for KDF 150 – 800 A: 82 Code No for KDF 800 – 1250 A: 83 -
HER 1 (Long)
Vertical Protection Relay, Vertical Protection RelayVertical Protection Relay for Hermetic Transformators (with contact) (IP65)
Type: HER 1 (Long) Switch Rating: 5A125VAC 3A250VAC Operating Pressure (bar): 0.50 -
HER 2 (Short)
Vertical Protection Relay, Vertical Protection RelayVertical Protection Relay for Hermetic Transformators (with contact) (IP65)
Type: HER 2 (Short) Switch Rating: 5A125VAC 3A250VAC Operating Pressure (bar): 0.50 -
HV Bushings 52kV and from 1000A to 3150A (DIN 42534)
DIN BUSHINGS (HV-LV), DIN BUSHINGS (HV-LV)HV Bushings 52kV and from 1000A to 3150A (DIN 42534) -
HV Bushings from 12kV to 36kV and 250A – 3150 (DIN 42531, DIN 42532, DIN 42533)
DIN BUSHINGS (HV-LV), DIN BUSHINGS (HV-LV)HV Bushings from 12kV to 36kV and 250A – 3150 (DIN 42531, DIN 42532, DIN 42533) -
HV Bushings from 12kV to 36kV and from 250A to 3150A (EN 50180)
EN BUSHINGS (HV-LV), EN BUSHINGS (HV-LV)HV Bushings from 12kV to 36kV and from 250A to 3150A (EN 50180) -
KDF II Type Linear Tap Changer
(DECT) TAP CHANGERS (LINEER - ROTARY), (DECT) TAP CHANGERS (LINEER – ROTARY)Linear Type: KDF II Voltage (kV): 20 - 30 - 60 Current (A): 150 - 400 Number of Positions: 2 - 11 Connection: Delta, Star, Series–Parallel, Common–Output per Phase -
KDF III Type Linear Tap Changer
(DECT) TAP CHANGERS (LINEER - ROTARY), (DECT) TAP CHANGERS (LINEER – ROTARY)Linear Type: KDF III Voltage (kV): 20 - 30 Current (A): 400 - 800 Number of Positions: 2 - 9 Connection: Delta, Star, Series–Parallel, Common–Output per Phase -
KDF IV Type Linear Tap Changer
(DECT) TAP CHANGERS (LINEER - ROTARY), (DECT) TAP CHANGERS (LINEER – ROTARY)Linear Type: KDF IV Voltage (kV): 20 - 30 Current (A): 800 - 1800 Number of Positions: 2 - 5 Connection: Delta, Star, Series–Parallel -
KDM Type Linear Tap Changer
(DECT) TAP CHANGERS (LINEER - ROTARY), (DECT) TAP CHANGERS (LINEER – ROTARY)Linear Type: KDM Voltage (kV): 20 - 30 Current (A): 30 - 63 - 120 Number of Positions: 2 - 7 Connection: Delta, Star, Series–Parallel -
KDV Rotary Type Tap Changer
(DECT) TAP CHANGERS (LINEER - ROTARY), (DECT) TAP CHANGERS (LINEER – ROTARY)Rotary Type: KDV Voltage (kV): 24 Current (A): 100 - 300 Number of Positions: 2 - 6 Connection: Delta -
KDZ Type Linear Tap Changer
(DECT) TAP CHANGERS (LINEER - ROTARY), (DECT) TAP CHANGERS (LINEER – ROTARY)Linear Type: KDZ Voltage (kV): 10 - 15 - 20 - 30 Current (A): 30 - 63 - 120 Number of Positions: 2 - 11 Connection: Delta, Star, Series–Parallel -
LV Bushings 1kV and from 250A to 3150A (DIN 42530)
DIN BUSHINGS (HV-LV), DIN BUSHINGS (HV-LV)LV Bushings 1kV and from 250A to 3150A (DIN 42530) -
LV Bushings 1kV and from 250A to 5000A (EN 50386)
EN BUSHINGS (HV-LV), EN BUSHINGS (HV-LV)LV Bushings 1kV and from 250A to 5000A (EN 50386) -
LV Bushings 3kV and from 250A to 3150A (DIN 42539)
DIN BUSHINGS (HV-LV), DIN BUSHINGS (HV-LV)LV Bushings 3kV and from 250A to 3150A (DIN 42539) -
Machine Glass Thermometer (DIN 16160-3)
THERMOMETERS, THERMOMETERS, With Contact, With ContactType: ST 130 Probe Length (mm): 63 - 100 Working Liquid: Alcohol Measuring Range: -200C ~ 1200C Connections Diameter: G ½” Pocket Diameter: 12 mm -
Magnetic Oil Level Indicators (DIN 42569)
OIL LEVEL INDICATORS (OLI), OIL LEVEL INDICATORS (OLI)p { margin: 0 0 -6px !important; } Type: KYSA - B0 KYSA - B1 KYSA-B2 Number of Switch: 0 1 2 Sweep Angle (°): 140 Working range: - 25°C / + 120°C Switch Rating: 5A125VAC 3A250VAC
Type: KYSB - B0 KYSB - B1 KYSB-B2 Number of Switch: 0 1 2 Sweep Angle (°): 100 Working range: - 25°C / + 120°C Switch Rating: 5A125VAC 3A250VAC
Type: KYSC - B0 KYSC - B1 KYSC-B2 Number of Switch: 0 1 2 Sweep Angle (°): 120 Working range: - 25°C / + 120°C Switch Rating: 5A125VAC 3A250VAC
Type: KYSD - B0 KYSD - B1 KYSD-B2 Number of Switch: 0 1 2 Sweep Angle (°): 120 Working range: - 25°C / + 120°C Switch Rating: 5A125VAC 3A250VAC
Type: KYSD - B0 KYSD - B1 KYSD-B2 Number of Switch: 0 1 2 Sweep Angle (°): 120 Working range: - 25°C / + 120°C Switch Rating: 5A125VAC 3A250VAC
Type: KYSE - B0 KYSE - B1 KYSE-B2 Number of Switch: 0 1 2 Sweep Angle (°): 120 Working range: - 25°C / + 120°C Switch Rating: 5A125VAC 3A250VAC -
Magnetic Oil Level Indicators (DIN 42569) (without contact)
OIL LEVEL INDICATORS (OLI), OIL LEVEL INDICATORS (OLI)Square Type Type: KSS A KSS B Flange Dimension (mm): 60x60 80x80 Sweep Angle (°): 100 100 Floater Length min/max (mm): 88/308 88/308 Circular Type Type: KSS F KSS G Flange Dimension (mm): Ø80 Ø100 Sweep Angle (°): 117 125 Floater Length min/max (mm): 88/308 88/308 -
NAK (Special Type)
MOISTURE HOLDERS, MOISTURE HOLDERSType: NAK Silica Gel Capacity (kg): 0.15 Reservoir Material: Glass / Polycarbonate -
Oil Level Indicators (OLI)
COMEMLevel gauges with magnetic joint: https://emdltd.com.tr/wp-content/uploads/2019/06/Level-gauges-with-magnetic-joint-L14-L22-L34_GB.pdf -
Pressure Relief Devices
QUALİTROLPressure Relief Devices: https://emdltd.com.tr/wp-content/uploads/2019/06/Pressure-Relief-Devices.pdf AP-P05-01L-01E_141: https://emdltd.com.tr/wp-content/uploads/2019/06/AP-P05-01L-01E_141.pdf AP-P05-04A-01E_070-351: https://emdltd.com.tr/wp-content/uploads/2019/06/AP-P05-04A-01E_070-351.pdf AP-P06-01A-01E_900_910: https://emdltd.com.tr/wp-content/uploads/2019/06/AP-P06-01A-01E_900_910.pdf About Qualitrol: https://emdltd.com.tr/wp-content/uploads/2019/06/Qualitrol.pdf -
Pressure Relief Valves (PRV)
COMEM50 and 25 VG Safety Valve: https://emdltd.com.tr/wp-content/uploads/2019/06/50-and-25-VG-Safety-Valve.pdf T and Q Pressure Relief Valve: https://emdltd.com.tr/wp-content/uploads/2019/06/T-and-Q-Pressure-Relief-Valve.pdf -
Remote Mount Thermometers
THERMOMETERS, THERMOMETERS, With Contact, With ContactType: RMTS 3 RMTS 5 Capillary Length (m): 3 5 Measuring Principle: Capillary (Gas Filled) Dial Diameter: 100 - 160 Measuring Range: 00C ~1200C / 00C ~1600C -
Shutter Valve
COMEMRDR-MK II shutter valve: https://emdltd.com.tr/wp-content/uploads/2019/06/RDR-MK-II-shutter-valve.pdf -
T – 0,5
Without Contact, Without ContactType: T - 0,5 Connections Diameter: 1/2” – 14 NPT Working pressure range (bar): 0.35 – 0.70 -
T – 10
Without Contact, Without ContactType: T - 10 Connections Diameter: R1” – R1 ½” – R2” Working pressure range (bar): 0.20 - 0.70 -
T – 10K1
Without Contact, Without ContactType: T - 10K1 Connections Diameter: R1” – R1 ½” – R2” Working pressure range (bar): 0.20 - 0.70 -
T – 50
With Contact (IP65), With Contact (IP65)Type: T - 50 Contact System: Mechanical Working pressure range (bar): 0.30 - 0.80 Switch Rating: 5A 125VAC - 3A 250VAC / 10A 250VAC -
T – 80
With Contact (IP65), With Contact (IP65)Type: T - 80 Contact System: Mechanical Working pressure range (bar): 0.30 - 0.80 Switch Rating: 240V 3A (Ith=10A) -
Tap Changers
COMEMMT Series Tap Changer and Motor Drive: https://emdltd.com.tr/wp-content/uploads/2019/06/MT-Series-Tap-Changer-and-Motor-Drive.pdf Off circuit TKC series:https://emdltd.com.tr/wp-content/uploads/2019/06/Off-circuit-TKC-series.pdf -
Termometers
QUALİTROLAKM44650: https://emdltd.com.tr/wp-content/uploads/2019/06/AKM44650.pdf AP-T01-03L-01E 165-167: https://emdltd.com.tr/wp-content/uploads/2019/06/AP-T01-03L-01E_165-167.pdf AP-T01-04L-03E 44612: https://emdltd.com.tr/wp-content/uploads/2019/06/AP-T01-04L-03E_44612.pdf AP-T03-02L-01E AKM 48003: https://emdltd.com.tr/wp-content/uploads/2019/06/AP-T03-02L-01E_AKM_48003.pdf AP-T02-03L-02EN: https://emdltd.com.tr/wp-content/uploads/2019/06/quorıtrol-AP-T02-03L-02EN2.pdf About Qualitrol: https://emdltd.com.tr/wp-content/uploads/2019/06/Qualitrol.pdf -
Transformer Wheels (DIN 42561)
TRANSFORMERS WHEELS, TRANSFORMERS WHEELSType: ø125 x 6 ø125 x 10 ø160 x 10 ø200 x 10 Carrying Capacity (kg): 1200 2500 3500 6000 -
Transformer Wheels Form W (with Locked Modified DIN 42561)
TRANSFORMERS WHEELS, TRANSFORMERS WHEELSType: ø125 x 6 ø125 x 10 ø160 x 10 ø200 x 10 Carrying Capacity (kg): 1200 2500 3500 6000 -
Transformer Wheels Form X
TRANSFORMERS WHEELS, TRANSFORMERS WHEELSType: ø125 Carrying Capacity (kg): 2500 -
Transformer Wheels Form Y
TRANSFORMERS WHEELS, TRANSFORMERS WHEELSType: ø50 ø70 ø80 ø90 Carrying Capacity (kg): 500 1500 3000 4500 -
Transformer Wheels Form Z (with Bolt Modified DIN 42561)
TRANSFORMERS WHEELS, TRANSFORMERS WHEELSType: ø125 x 10 ø160 x 10 ø200 x 10 Carrying Capacity (kg): 2500 3500 6000 -
V – 125
Without Contact, Without ContactType: V – 125 Bore Diameter (mm): 125 Working pressure range (bar): 0.25 - 0.80 -
V – 50
Without Contact, Without ContactType: V – 50 Bore Diameter (mm): 50 Working pressure range (bar): 0.30 - 0.70 -
V – 80
Without Contact, Without ContactType: V – 80 Bore Diameter (mm): 80 Working pressure range (bar): 0.30 - 0.70 -
Vertical Oil Level Indicators (without contact)
OIL LEVEL INDICATORS (OLI), OIL LEVEL INDICATORS (OLI)Type: KSS C Connections: 1” Type: KSS D Connections: 1” – 1 ¼” – 1 ½” – 2” Sweep Distance (mm): 40 Type: KSS E Connections: 1 ½” Sweep Distance (mm): 90 Type: KSS P Dimensions (mm): 65x100 / 65x180 / 65x250
EMD Industrial Equipments > Shop